Sign In | Join Free | My frbiz.com
China Henan Jinzhen Boiler Co., Ltd. logo
Henan Jinzhen Boiler Co., Ltd.
Jinzhen Boiler, warm you every moment!
Site Member

6 Years

Home > Thermal Fluid Heater >

1.6MW 1900kw Horizontal Hot Oil Industry Thermic Fluid Heater Thermal Oil Boiler For Road Construction

Henan Jinzhen Boiler Co., Ltd.

1.6MW 1900kw Horizontal Hot Oil Industry Thermic Fluid Heater Thermal Oil Boiler For Road Construction

Brand Name : Jinzhen Boiler

Model Number : 1900kw Thermal Fluid Heater

Certification : CE

Place of Origin : China

MOQ : 1 set

Price : USD 10000-20000 per set

Payment Terms : L/C, T/T, Western Union

Supply Ability : 300 Set/Sets per Year

Delivery Time : 15 work days

Packaging Details : Export standard seaworthy packing

Item : Thermal Fluid Heater, thermal oil boiler

Structure : Coil Type

Pressure : Low Pressure

Style : Horizontal

Fuel : Natural Gas, LPG, Diesel

Output : High Temperature Thermal Fluid Oil

Heating Capacity (Kcal) : 1600000Kcal per hour, 16MW Kcal

Heating Capacity (Kw) : 1900kw

Thermal Fluid Oil Temperature : ≤320℃

Working Pressure : ≤10Bar

Control System : PLC, Touch Screen, English Language

Structure Type : Skid-Mounted

Installation Method : Free-Installation

Application Field : Timber Industry, Oil Refining, Heat Drying

Contact Now

Horizontal Hot Oil Industry Thermic Fluid Heater Thermal Oil Boiler For Road Construction

Heat Transfer Fluid heaters (hot oil heater) to oil (gas) as fuel to oil as medium, using hot oil circulation pumps mandatory medium for liquid circulation, the energy delivery device and then return to Heat re-heating furnace with low pressure in the working temperature was high, and can run on medium high-precision control. System with high thermal efficiency, due to the overall module installation, operation and easy maintenance, is a safe, efficient, energy saving ideal choice for heating equipment.

Fuel oil (gas) from the burner flame after ignition temperature generated within the coil to form into the radiation heating surface, through the internal coil rotated by 180 °into the rear forward, the foreign control of the mezzanine area convection heating surface. Then enter the upper mezzanine, the outer coil of the second mezzanine area, in the second mezzanine area to the rear of the chimney into the atmosphere.

Technique data:

Rated thermal power is 0.12Mw (10×104kcal/h) to 16Mw (160×104kcal/h).

Design pressure is equal to or greater than 1 Mpa.

Operating temperature is equal to or less than 350°C.

Thermal efficiency is between 60% and 85% according to the difference of boiler type.

Technical Parameters

Model No. Thermal power(kcal/h)

Heating efficiency

(%)

Max. working temp.(℃) Medium circulation(M3/H)

Transport size

(mm)

Weight

(Kg)

YY(Q)W-120Y(Q) 10*104 ≥92.26 340 12.5 Φ1060*2045 1215
YY(Q)W-240Y(Q) 20*104 ≥92.26 340 18 Φ1020*1980 1355
YY(Q)W-350Y(Q) 30*104 ≥92.26 340 30 Φ1212*2310 1590
YY(Q)W-500Y(Q) 40*104 ≥92.26 340 30 Φ1212*2730 1680
YY(Q)W-700Y(Q) 60*104 ≥92.26 340 60 Φ1400*3410 2715
YY(Q)W-900Y(Q) 80*104 ≥92.26 340 80 Φ1616*3400 3142
YY(Q)W-1200Y(Q) 100*104 ≥92.26 340 100 Φ1616*4000 3660
YY(Q)W-1400Y(Q) 120*104 ≥92.26 340 100 Φ1820*4905 5420
YY(Q)W-2000Y(Q) 160*104 ≥92.26 340 100 Φ1840*4950 7850
YY(Q)W-2400Y(Q) 200*104 ≥92.26 340 160 Φ2060*4700 8850
YY(Q)W-3000Y(Q) 250*104 ≥92.26 340 180 Φ2060*5450 9210
YY(Q)W-3500Y(Q) 300*104 ≥92.26 340 200 Φ2430*5965 9960
YY(Q)W-4100Y(Q) 350*104 ≥92.26 340 250 Φ2630*6990 1120
YY(Q)W-4700Y(Q) 400*104 ≥92.26 340 250 Φ2830*7100 1230

oil fired thermic fluid heater hot oil boilerThe Gas/Oil Fired thermal oil boiler auxiliaries :

Name Quantity(unit/piece)
main body of thermal oil boiler 1
Oil Circulating pump 1
Gas/oil burner 1
oil filling pump 1
Filter 1
Electric control cabinet 1
high level oil storage tank 1
Low level oil storage tank 1
Valves and gauges one batch for whole system

Free-Installation

The complete boiler system is well skid-mounted on the basement, also we have done the pipe(valves) connection and wire connection. After receiving the boiler, user no need to do installation, just filling the thermal fluid oil, join the fuel and electricity. Entire boiler system is portable.

Boiler advantage

1.Prolong the boiler service life according to the cloesed circulation heating, and protect the environment.

2.Increase the heating area by adopting the pipe coil structure.

3. There is a backup circulation pump. Once the circulating pump is not available at the time, the backup circulation pump works immediately.

4.Precise temperature control byu adopting complete running and safety monitoring devices.

Application of thermal oil system

The series of thermal oil heater is widely used in the following industries:

l Petrochemical Industries:polymerization, melted, condensation, distillation, removal H2.

l Oil industry:fat and acid distillation, grease decomposition, concentrated, esterification, vacuum deodorizer, high-temperature cooking, advanced salad oil.

l Synthetic fiber industry: polymerization, melt spinning, extending; drying.

l Textile printing and dyeing industry: heat setting, hot melt dyeing, melt bake calendering drying, high temperature stenter, oar yarn.

l Plastics and rubber industry:hot pressing, hot cast, vulcanization molding, calendering injection machine, plastic mixer, conveyor dryer, screw extruder.

l Paper Industry: dry, corrugated paper processing, egg tray, food cardboard drying, calendering machine, roller.

l Timber industry: multilayer plywood, fiberboard molding, plywood, wood drying, steaming equipment.

l Building materials industry: road bitumen heating, gypsum board drying, heating bitumen concrete, concrete elements curing, drying equipment.

l Air-conditioning industry:industrial plants, residential and hotel building heating.

l Detergent Industry: cooking boiler, autoclave, spray-washing tower, a conveyorized dryer, lipolysis device distillation column.

l The automotive industry:the tunnel-type drying room, degreasing baths, phosphate processing equipment.

l Electrical equipment industry: calendering machine, the platen machines, vacuum pan, dryer.

FAQ

1.What is the highest temperature that thermal oil heater could achieve?

thermal oil heater can reach as high as 330℃, and working under low pressure (<1.0MPa)

2.What are the heat-resistance temperature of grate and furnace?

The heat resistance temperature of grate is related to the grate material, the highest temperature could be as high as 1100℃, and the lower temperature could be 700℃.

The highest heat resistance temperature of furnace could be about 1700℃~1800℃.

3.What is conduction oil/ hot oil / heat transfer fluid?

Conduction oil has a high boiling point, it usually used for the industries that need the temperature of 150~350℃, to instead of steam. The hot oil has the advantages of high transfer efficiency, fast heat transfer, and good thermal stability.

1.6MW 1900kw Horizontal Hot Oil Industry Thermic Fluid Heater Thermal Oil Boiler For Road Construction

1.6MW 1900kw Horizontal Hot Oil Industry Thermic Fluid Heater Thermal Oil Boiler For Road Construction

1.6MW 1900kw Horizontal Hot Oil Industry Thermic Fluid Heater Thermal Oil Boiler For Road Construction1.6MW 1900kw Horizontal Hot Oil Industry Thermic Fluid Heater Thermal Oil Boiler For Road Construction


China 1.6MW 1900kw Horizontal Hot Oil Industry Thermic Fluid Heater Thermal Oil Boiler For Road Construction wholesale

1.6MW 1900kw Horizontal Hot Oil Industry Thermic Fluid Heater Thermal Oil Boiler For Road Construction Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Henan Jinzhen Boiler Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)
 

Friendly Links: www.everychina.com

Home| Products| Suppliers| Quality Suppliers| Site Map |About Us |Help

Copyright © 2009 - 2024 frbiz.com. All rights reserved.